Riso RN SERIES Technical Manual page 256

Table of Contents

Advertisement

CHAPTER 15. PANEL MESSAGES
DETAILS OF PANEL MESSAGES
Error type
T08 [CI error]
T08-***
A problem has occurred.
Panel display
Switch on power again.
If resetting is not possible, notify technician of T08-***.
Reset method Switch on power again.
Error point
002
CI communication error
Error type
T11 [Pressure control motor lock]
T11-***
A problem has occurred.
Panel display
Press the lower right "Jam Reset" key.
If resetting is not possible, notify technician of T11-***.
Jam reset -> Recovery operation (home position reset)
Reset method
Or: switch on power again.
Error point
Print pressure control sensor does not go OFF -> ON even when the pressure control motor
600
is moved 3200 pulses in the direction of compression when setting the pressure control
home position.
Print pressure control sensor does not go ON -> OFF even when the pressure control motor
601
is moved 3200 pulses in the release direction when setting the pressure control home
position.
Print pressure control sensor does not go OFF -> ON even when the pressure control motor
602
is moved 10 pulses to check the home position when setting the pressure control home
position.
Error type
T12 [Master removal motor lock]
T12-***
A problem has occurred.
Panel display
Press the lower right "Jam Reset" key.
If resetting is not possible, notify technician of T12-***.
Reset method Jam reset -> Recovery operation
Error point
300
Master removal motor (vertical transport motor) overload current detection is ON.
Master compression sensor does not go ON within 7 s after the master compression motor
305
operates in the return direction.
Master compression sensor does not go OFF within 400 ms after the master compression
306
motor operates in the direction of compression.
Master compression sensor does not go ON within 11 s after the master compression motor
307
operates in the direction of compression.
Master compression sensor does not go OFF within 3 s after the master compression
309
motor operates in the return direction.
Error conditions
Error conditions
Error conditions
15 – 6