Riso RN SERIES Technical Manual page 282

Table of Contents

Advertisement

No.
Name
380
Jam removal detection angle 1
Description Sets the first print drum angle for checking jam removal.
Range: 0 - 3600 (0° - 360°)
Setting
Units:
Default: 700 (70°)
381 Jam removal detection angle 2
Description Sets the second print drum angle for checking jam removal.
Range: 0 - 3600 (0° - 360°)
Setting
Units:
Default: 900 (90°)
382
Master removal motor stop timing
Description Sets master-removal-motor stop timing after the print drum stops at position A.
Range: 0 - 2000 (0 s - 2 s)
Setting
Units:
Default: 0 s
384
Master compression plate return timing
Sets master-compression-plate stop timing after moving to the compression
Description
position until it starts to return.
Range: 0 s - 100 s
Setting
Units:
Default: 1 s
386
Master disposal box count
Description Sets count for full master disposal box.
Range: 40 - 50
Setting
Units:
Default: 50
387
Master removal print drum speed
Sets the print drum speed for master removal.
Description
* Master removal feed motor speed is fixed.
Range: 10 - 60 rpm
Setting
Units
Default: 15 rpm
389
Software count clear
Description Clears program count for removed masters.
Setting
None
10 (1°)
10 (1°)
10 (0.01 s)
1 s
1
5 rpm
16 – 15