6.

Data Setting

(1) Press the "Start" key to display and operate the data currently set.
(2) Change data using the numeric keys. Switch to the ± display using the "*" key.
(3) Once settings have been changed, press the "Enter" or "Start" key to confirm the data and return to
standby.
* Settings will be changed to their default values if values outside the setting ranges are entered.
No.
Name
080
Jam clear
Description
Setting
081
Memory clear (user area)
Description
Setting
082
Test mode data setting clear
Description
Setting
083
Maintenance master count setting
Description Sets the number of masters at which the call-technician message is displayed.
Setting
084
Maintenance main unit print count setting
Description
Setting
085
Maintenance print-drum print count setting
Description
Setting
087
Maintenance count clear (master creation)
Description
Setting
088
Maintenance count clear (printing)
Description
Setting
089
Maintenance count clear (print drum)
Description
Setting
Forcibly clears jam.
Consumable errors cannot be cleared.
None
Resets settings (memory, user mode, timers) other than Test mode data settings,
type codes, print drum codes, and ink codes to their default values.
* Always save data before resetting.
None
Resets all settings set in Test modes to defaults values.
* Always save data before resetting.
None
Range: 0 - 9999 (*100)
Units:
1 (*100)
Default: 0
Sets the number of main unit prints at which the call-technician message is
displayed.
Range: 0 - 9999 (*1000)
Units:
1 (*1000)
Default: 0
Sets the number of print-drum prints at which the call-technician message is
displayed. (Set for each print drum.)
Range: 0 - 9999 (*1000)
Units:
1 (*1000)
Default: 0
Clears the master count (within software) for displaying technician call message
the call-technician message.
None
Clears the print count (within software) for displaying technician call message the
call-technician message.
None
Clears the print-drum print count (within software) for displaying technician call
message the call-technician message.
None
16 – 11
RN (Version 1.0)
CHAPTER 16. TEST MODE