CHAPTER 10. MASTER REMOVAL SECTION
REMOVING THE MASTER REMOVAL UNIT
2.
Removing the Master Removal Unit
(1) Move the scanner table to the servicing position [A].
(2) Remove the front and rear covers.
(3) Remove the upper housing cover (master removal unit cover). (M3 x 6: 2 pcs)
(4) Unlock the Release lever [B], fully open the Master disposal gate housing [C], and pull out the master
disposal gate housing horizontally in the direction of paper ejection. The master disposal gate
housing is slotted into the Pivot shafts [D] on both sides. The shafts are cut as shown in the diagram
below, and so the master disposal gate housing can be pulled out provided it is opened sufficiently.
C
A: Servicing position
B: Release lever
C: Master disposal gate housing
D: Pivot shaft
B
D
10 – 10
RN (Version 1.0)
A