Riso RN SERIES Technical Manual page 281

Table of Contents

Advertisement

CHAPTER 16. TEST MODE
DATA SETTING
No.
Name
280
Master setting adjustment
Description
Setting
281 Master creation start position adjustment
Description
Setting
282
Master creation length adjustment
Description Adjusts the master creation area (width scanning length).
Setting
283
Clamp range adjustment
Description Adjusts master clamp range when loading master.
Setting
284
Master overall length adjustment (cutting angle)
Description Adjusts the length of one master (cutting timing).
Setting
287
Master creation image elongation and shrinkage adjustment
Description Adjusts frequency setting for the master creation pulse motor.
Setting
Adjusts a small amount of return movement after the master positioning sensor
goes ON for inching operation during master setting or after master cutting.
Range: 0 - 50 (0 mm - 5.0 mm)
Units:
1 (0.1 mm)
Default: 20 (2.0 mm)
Adjusts the master creation start position (distance from master positioning
sensor ON to read/write signal ON).
Range: -30 - +50 (-3.0 mm - +5.0 mm)
Units:
1 (0.1 mm)
Default: 0 mm
Range: -100 - +100 (-10.0 mm - +10.0 mm)
Units:
1 (0.1 mm)
Default: 0 mm
Range: -100 - +100 (-10.0 mm - +10.0 mm)
Units:
1 (0.1 mm)
Default: 0 mm
Range: -100 - +200 (-10.0° - +20.0°)
Units:
1 (0.1°)
Default: 0°
Range: -100 - +100 (-10.0%- +10.0%)
Units:
1 (0.1%)
Default: 0%
16 – 14
RN (Version 1.0)
* (+ is downward)
* (+ increases length)
* (+ increases clamp range)
* (+ increases master length)
* (+ elongates)