Barco S3 User Manual page 148

Event master devices
Hide thumbs Also See for S3:
Table of Contents

Advertisement

6. EM GUI orientation
Connect the Link cables provided with each unit between the Link connectors as follows:
E2 VP ID 0, Link Card slot 1, Link 1 >> S3 VP ID 1, Link Card slot 1, Link 2
E2 VP ID 0, Link Card slot 1, Link 2 >> S3 VP ID 1, Link Card slot 1, Link 1
E2 VP ID 0, Link Card slot 2, Link 1 >> EX VP ID 2, Link 2
EX VP ID 2, Link 1 >> EX VP ID 3, Link 2
E2 VP ID 0, Link Card slot 2, Link 2 >> EX VP ID 4, Link 2
EX VP ID 4, Link 1 >> EX VP ID 5, Link 2
See image 6-33 for an example of the cabling between an E2 unit, an S3-4K unit, and four EX units.
Image 6-33
Cabling between an E2 unit, an S3–4K unit, and four EX units
Event Master Configuration
1. Start the Event Master Toolset version 4.1 or higher.
2. Make sure that the E2, the S3–4K, and the EX are discovered on the network and that they have different Unit IDs.
3. Drop the E2 in the GUI.
144
R5905948 EVENT MASTER DEVICES 17/07/2017

Advertisement

Table of Contents
loading

Table of Contents