13. E2 Maintenance

13.31 1RU Fan Cable

The 1RU cable assembly provides power to the 1RU fans from the System-Power board.
One side of the cable is attached to a metal bracket that is accessible after the 3RU and the 1RU fan trays are
removed. The other side of the cable assembly connects to the System-Power board and is accessible when
the bottom panel is removed.
Concerned parts
R767269K
Cable Kit Set
Necessary tools
1 x Phillips Screwdriver #2
Hex Screwdriver
How to remove the 1RU Fan cable
1. Make sure the unit is placed in the upright position and the 3RU and 1RU fan trays are removed.
2. Locate the 1RU cable connector that is exposed after the 1RU fan tray is removed. The connector is attached on a metal bracket
that is horizontally mounted in the chassis.
404
Image 13-82
R5905948 EVENT MASTER DEVICES 17/07/2017