10.6 Connecting Leads to a Spring Clamp Terminal Block

The unit is delivered with two terminal block connectors. The connectors enable you to connect
wires for either the relay output or alarm input and then connect them to the unit.
To connect a wire to the spring clamp terminal block
1. Strip the insulation form the end of each wire that is to be connected to the terminal
block. Approximately 1 cm (2.54") of wire should be exposed.
2. With a small screwdriver, press in and hold the orange spring clamp button next to the
female outlet where the wire will be inserted.
3. Insert the stripped end of the wire into the female outlet.
4. Release the orange spring clamp button.
148
Spring Clamp Terminal Block
Connecting a Wire to a Terminal Block
CP-3211/CP-4221 User and Installation Guide