Chapter 2
enter the appropriate card number (1 to 2001).
-Use the number that is the lowest of all the numbers that the user will be using.
-As many as 1000 cards may be used starting with the number entered.
13) Turn off the control panel power switch.
14) Turn off and then on the main power switch.
2.6.4 Installation in a NetSpot Accountant (NSA) Environment
iR2270 / iR2870
1) Make the following selections in user mode: system control setup>group ID control>count control; then, see that
the following numbers are available: ID00000001 to ID00001000. (If you entered '1' in service mode:
COPIER>FUNCTION>INSTALL>CARD.)
2) Make the following selections in user mode: system setup>network setup>TCP/IP setup>IP address. Set the
following: 'IP address', 'gateway address', 'subnet mask'.
Unless you have set 'system control group ID' and 'system control ID No.', you will not be able to execute 'register
card to device' as part of NSA setup work.
3) In user mode, enter numbers of your choice for 'system control ID' and 'system control ID No.' as part of system
administrator information.
4) Turn off the control panel power switch.
5) Turn off and then on the main power switch.
2-32
0007-2764