Code
Cause
0002
While output is being generated, the AD
value of the primary DC voltage is 230
(DEC) or more for 100 msec 2 times in
sequence. (However, after output, it is
not detected for 100 msec.)
0003
While output is being generated, the AD
value of the developing DC voltage is
224 (DEC) or more for 10 msec 2 times
in sequence. (However, after output, it is
not detected for 100 msec.)
0004
While output is being generated, the AD
value of the transfer output current is 205
(DEC) or more for 100 msec 2 times in
sequence. (However, after output, it is
not detected for 100 msec.)
0005
While output is being generated, the AD
value of the transfer output voltage is 0
(DEC) for 100 msec 2 times in sequence.
(However, after output, it is not detected
for 100 msec.)
E100
The BD interval is outside a specific range.
0001
After the machine has become ready for
image formation (i.e., the scanner motor
is ready for operation, and the laser has
been turned on), an error has occurred 50
times or more (BD error).
E110
The scanner motor is faulty.
0001
The scanner motor speed lock signal does
not indicate a locked state a specific
period of time after the scanner motor has
been started.
0002
The speed lock signal indicates a
deviation 10 times in sequence at
intervals of 10 msec after the signal has
indicated a locked state.
0003
With the image clock switched over, the
scanner motor speed lock signal does not
indicate a locked state 6.5 sec after a
switchover is made from low to normal
speed or 8 sec after a switchover is made
from normal to low speed.
Remedy
Replace the high-voltage power supply.
Replace the DC controller PCB.
Replace the high-voltage power supply.
Replace the DC controller PCB.
Replace the high-voltage power supply.
Replace the controller PCB.
Replace the high-voltage power supply.
Replace the DC controller PCB.
Replace the laser unit. Replace the DC
controller PCB. Check the wiring.
Replace the laser unit. Replace the DC
controller PCB. Check the wiring.
Replace the laser unit. Replace the DC
controller PCB. Check the wiring.
Replace the laser unit. Replace the DC
controller PCB. Check the wiring.