Code
Cause
0000
While startup control is under way, the
reading of the main thermistor is less than
115 deg C continuously for 400 msec 1.3
sec after it has indicated 100 deg C.
While startup control is under way, the
reading of the main thermistor is less than
150 deg C continuously for 400 msec 1.3
sec after it has indicated 140 deg C.
E003
The fixing temperature is too low after a standby state.
0000
While regular temperature control is
under way, the reading of the main
thermistor is less than 140 deg C
continuously for 400 msec or more.
E007
The rotation of the fixing film is faulty.
0000
While the fixing motor is rotating, the
marker signal is not detected for 6 sec
with the reading of the main thermistor
indicating 100 deg C or more.
E010
The rotation of the main motor is faulty.
0001
Detection is executed every 100 msec
after the start of motor rotation; however,
the drive detection signal is absent for 2
sec.
0002
During motor rotation, detection is
executed every 100 msec; however, the
drive signal is absent 5 times in sequence.
E014
The rotation of the fixing motor is faulty.
0001
Detection is executed every 100 msec
after the start of motor rotation; however,
the drive detection signal is absent for 2
sec.
0002
During motor rotation, detection is
executed every 100 msec; however, the
drive signal is absent 5 times in sequence.
E019
The waste toner case is full, or the waste toner case full sensor is faulty.
Remedy
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Replace the main thermistor. Replace the
DC controller PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Replace the main thermistor. Replace the
DC controller PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Replace the main thermistor. Replace the
DC controller PCB.
Replace the main motor. Replace the DC
controller PCB.
Replace the main motor. Replace the DC
controller PCB.
Replace the fixing motor. Replace the DC
controller PCB.
Replace the fixing motor. Replace the DC
controller PCB.