F-7-200
4) Remove the 3 screws [1], and detach the hopper
assembly [2].
F-7-201
When fitting the hopper assembly to the machine, be
sure that the connectors [1] are securely connected. If
the connectors [1] are not connected, the environment
heater will not be supplied with power, leading to
image faults.
F-7-202
7.12.9.12 Removing the Toner
Level Sensor
iR2270 / iR2870 / iR3570 / iR4570 / iR3530
1) Remove the 2 screws [1], and disconnect the
connector [2]; then, detach the toner sensor [3].
F-7-203
7.12.10 Toner Feedscrew Motor
7.12.10.1 Removing the Front
Cover Unit
iR2270 / iR2870 / iR3570 / iR4570 / iR3530
1) Open the front cover [1].
F-7-204
2) Remove the face cover rubber [1].
3) Remove the binding screw [2].
4) Remove the RS tightening screw [3].
5) Detach the front cover unit [4] by moving it in the
direction of the arrow.
Chapter 7
0007-8373
0007-8019
7-63