TEMP-CON
Switching thick-paper fixing temperature mode
<Setting range>
0: OFF [Default]
1: Priority to productivity, control temperature fixed at -10deg C
2: Control temperature fixed at -6deg C
3: Control temperature fixed at -3deg C
4: Priority to fixing, control temperature fixed at +3deg C
5: Control temperature fixed at +6deg C
6: Control temperature fixed at +10deg C
7: Control temperature fixed at +15deg C
PRIAC-SW
Improving the image quality in case of a drum charging fault
Note: This setting is cleared if APVC is executed with a new drum unit
or if a service mode (FUNCTION>D-GAMMA) is executed.
<Setting range>
0: No UP [Default], 1: 50 mA UP, 2: 100 mA UP
TEMPCON2
Improving fixing (Increasing the fixing temperature)
Note: Valid for iR3570/3570F/4570/4570F only
<Setting range>
0: OFF [Default]
1: Priority to productivity, control temperature fixed at -10deg C
2: Control temperature fixed at -6deg C
3: Control temperature fixed at -3deg C
4: Priority to fixing, control temperature fixed at +3deg C
5: Control temperature fixed at +6deg C
6: Control temperature fixed at +10deg C
7: Control temperature fixed at +15deg C
COPIER > OPTION > BODY
Description