Flowchart 8-2
H
C
database, one program
to see if fault re-occurs.
Strata CT I&M Manual October 2000
Catastrophic Faults
Go to
Flowchart
8-1
2-4
Reprogram customer
at a time, and check
Yes
2-7
Does the fault
Yes
re-occur after
entering customer
database?
No
END
START
Is the system
No
completely
non-operational?
Yes
2-1
Test the Power Supply as
described in the Installation
Chapter. Also perform Hardware
Fault Isolation per
this chapter.
2-2
Was the fault
isolated by completing
the system hardware
check?
No
2-5
Re-initialise the system
(Programs 91-9 and 03)
and re-check fault using
default program data
(do not enter customer
database).
2-6
Was the
fault cleared
after re-initialising
the system?
No
2-8
Call your
technical support
group.
1880 CT I&M
Yes
Tag the defective
unit(s) and return
2-3
for repair.
Fault Finding
END