Advertisement

AC/Reserve Power and Data Cabling Overview

H
CHSUB672A
Cabinet 1
(base)
CHSUE672A
Cabinet 2
(expansion)
C
CHSUE672A
Cabinet 3
(expansion)
CHSUE672A
Cabinet 4
(expansion)
CHSUE672A
Cabinet 5
(expansion)
Data Cable
(supplied with expansion cabinet)
Figure 2-11
Strata CT I&M Manual October 2000
To avoid accidental turn off, do not configure the outlet serving the Strata CT with an On/Off
switch.
AC outlets serving the cabinets must be close enough so that the power cord from the cabinet
power supply or power strip can reach the outlet (these power cords are nine ft.)
AC wall outlets for the Strata CT must be on dedicated 20amp breakers. AC outlets must
meet ie Regs.
AC power cabling requirements vary, depending on: The method of cabinet installation
(floor or wall mount), AC power source voltage (240VAC) and the number of cabinets.
Requirements for distribution of AC power within the cabinets of the Strata CT are as
described in cabinet AC power distribution below.
Figure 2-11
shows an overview of the AC power and data cabling for the Strata CT. Detailed
illustrations of AC power strips and cords are on the following pages.
Motherboard
2
3
4
5
6
7
5046
Intercabinet Power/Data Cables
5 BBTC2A-2M battery cables
supplied with BBDB
Power Supply
BPSU672A
BATT
AC IN
BPSU672A
BATT
AC IN
BPSU672A
BATT
AC IN
BPSU672A
BATT
AC IN
BPSU672A
BATT
AC IN
Strata CT Installation
Power supply cord for:
• 240VAC - supplied
7925-P
Battery Distribution Box
• BBDB
Power Strip Cables
to Primary AC Power outlets
(9 ft.)
BBTC1A-2M Cables supplied with BBDB
to Reserve Power Batteries
(2 m.)
2-19