Toshiba strata CT Installation & Maintenance Manual page 199

Digital business telephone system
Hide thumbs Also See for strata CT:
Table of Contents

Advertisement

Configure PIOU, PIOUS or PEPU for External Page Mute Option
H
C
Figure 6-7
Strata CT I&M Manual October 2000
1.
Set Program 77-1 LED 07 to Off to configure the PIOU, PIOUS, or PEPU PCB for the external
page function.
2.
If using a PIOU or PEPU, set the jumper plug P10 on the PIOU or PEPU jumper plug to the
MAKE or BREAK position as required:
N
MAKE – Shorts the normally open contacts (pins 7 and 32) when external page is activated.
N
BREAK – Opens the normally closed contacts (pins 7 and 32) when external page is
activated.
...or
If using a PIOUS, solder the jumper W1 on the PIOUS to the MAKE or BREAK position as
required:
N
MAKE – Shorts the normally open contacts (DET and DER) when external page is activated.
N
BREAK – Opens the normally closed contacts (DET and DER) when external page is
activated.
3.
See Figures 6-7,
and
to the MDF as required for the external paging function.
PIOU/PEPU PCB
Select Relay Function
with Program 77-1
Door Lock or External
Page Control
Break
P10
Make
600Ω (Duplex)
SP0
SW4
Page or
BGM from
B_C_U
P11
Break
Make
Select Relay Function
with Program 77-1:
Night Relay or
MOH Control
Notes Dotted lines and solid lines differentiate optional connections where applicable; do not
connect both options simultaneously.
PIOU/PEPU Relay Control Functional Wiring Diagram
6-8
for wiring/interconnecting details. Connect the PIOU, PIOUS, or PEPU
PIOU 25 PR.
Connectors
PIN NO.
Colour
.
DE.T
32
R-O
.
DE. R
7
O-R
.
SP.T0
38
Bk-Gn
.
SP.R0
13
Gn-Bk
.
.
.
NH.T
34
R-Br
.
NH.R
9
Br-R
MDF
Connections
All wires should
be jacketed CW1308
0.5mm twisted pairs
Peripheral Installation
Door
Lock
Control
Page
Speaker
Amplifier
Tape
Player
Control
Night
To Music On-Hold
Bell
Input on CT KSU
1507
6-11