RSIU, RSIS, RMDS Programming

H
C
Strata CT I&M Manual October 2000
Program 03: Programs slot 11 with code 49 to identify that the RSIU PCB is installed in
slot 11.
Program 76-1X-Y: Assigns each installed RSIU port to a function. Where X identifies the
RSIU port no. 1~4 (see
Figure 3-14
RSIU port function:
N
Y=1, RS-232 TTY (Program 77-1, LED 14 Off)
N
Y=1, RMDS modem (Program 77-1, LED14 On)
N
Y=2, SMDR
N
Y=3, MIS or SMIS
N
Y=4, SMDI
N
Y=5, Open Architecture
N
Y=0, No function - this should be used for any of the four RSIU, RSIS, RMDS ports
that are not used.
Notes
Function codes set in Program 76-1X-Y will override RSSU, PIOU2, and/or
G
PIOUS2 function codes (41, 42, 43) set in Program 03.
The TTY and modem function cannot operate on separate RSIU, RSIS, RMDS ports
G
simultaneously. If both functions are programmed at the same time on separate
ports, the function of the lowest numbered RSIU, RSIS, RMDS port (TTY or
modem) will be active.
When uploading Program 76-1 with DK Admin, the data will not change until the
G
system power is cycled.
Program 76-2X-Z: Assigns each installed RSIU port to operate at a specified transmission
rate. Where X identifies the RSIU port no. 1~4 (see
configuration) and Z identifies the RSIU, RSIS, RMDS port transmission rate in bits-per-
second (bps).
Notes
The sum of the used RSIU, RSIS, RMDS ports transmission rates cannot exceed
G
9600 bps. Ports assigned as "non-function" (code 0) in Program 76-2X-Y will not be
included in the transmission rate sum. The RMDS will only function at 1200 or 2400
bps.
When uploading Program 76-2 with DK Admin make sure that Program 76-2 bps
G
rate for the TTY/ modem port is set the same in: DK Admin communications setup,
DK Admin customer database, and any Strata CT RCTU. If the bps rate is not the
same in all three areas, uploading will fail on Program 76
Program 77-1, LED 14: Enables the RMDS modem function. If the RMDS should function
as a modem, turn On LED 14. If the RMDS should function as a RS-232 port, turn Off LED
14.
Program 77-1, LED 15: Sets the RMDS communications standard type to CCITT/V.22bis
(2400 bps) or Bell 212A (1200 bps). The standard set in this program must match the
standard of the modem communicating with the Strata CT RMDS.
for RSIU port number configuration) and Y identifies the
Figure 3-14
Universal Slot PCBs
for RSIU port number
3-33