Communications - GE F650 User Manual

Grid solutions digital bay controller
Hide thumbs Also See for F650:
Table of Contents

Advertisement

CHAPTER 2: PRODUCT DESCRIPTION

2.5.10 Communications

FRONT PORT:
Front port:
Type:
Baud Rate:
Default Baud Rate:
Protocols:
Typical Distance:
Isolation:
ASYNCHRONOUS REAR PORTS:
None or two rear ports (depending on model):
Type (depending on model):
Model F
Model A
Model X
Model P
Model Y
Model G
Model Z
Model C
Model M
Optic Features for ST Connector Devices:
Baud Rate:
Default Baud Rate:
Protocols:
Typical Distance:
Isolation:
CAN PORT:
Rear Port:
Type:
Fiber Wavelength:
Fiber Type:
Maximum Recommended Length:
Isolation:
ETHERNET PORT:
Rear port:
For models B, C, D, E:
For models G, H, J, K, L, M:
Type (depending on model):
Model B:
Model C:
Model D:
Model E:
Model G:
Model H:
Model J:
Model K:
Model L:
Model M:
(*) Note: This Ethernet port (ETH_E) is intended only for maintenance purposes.
GEK-113000-AF
COM2
RS232/USB
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200 baud
19200 baud
®
ModBus
RTU/DNP 3.0
3 m
2 kV
COM1, COM2 (rear COM2 multiplexed with front port)
None
Redundant RS485
Redundant RS485 + fiber CAN for inputs/outputs module
Redundant 1mm-plastic F.O.
Redundant 1mm-plastic F.O. + fiber CAN for inputs/outputs module
Redundant multimode glass F.O.
Redundant multimode glass F.O. + fiber CAN for inputs/outputs module
Cable CAN port for I/O module
Cable CAN port for I/O module (cable) + RS485 (ModBus RTU)
Wave length: 1300nm
Fiber type: multimode 62.5/125 μm or 50/125 μm
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200 baud
19200 baud
®
ModBus
RTU/DNP 3.0/IEC103
1200 m for cooper cable, 1000 m for glass fiber and 50 m for plastic fiber
2 kV
CAN port in models C, M, X, Y, Z for asynchronous rear ports
Multimode glass F.O. port with ST connectors
820 nm
multimode 62.5/125 μm or 50/125 μm
300 m for cooper cable and glass fiber
2 kV
ETH_1/ ETH_2
ETH_E/ ETH_A/ ETH_B
10/100BaseTX self-negotiable
10/100BaseTX + 100Base FX
10/100BaseTX + redundant 100BaseFX (Physical media redundancy)
Redundant 10/100BaseTX self-negotiable ports
1588, 10/100 Base TX* + 100 Base TX
1588, 10/100 Base TX* + 100 Base FX
PRP, 1588, 10/100 Base TX* + Redundant 100 Base FX
PRP, HSR, RSTP, 1588, 10/100 Base TX* + Redundant 100 Base FX
PRP, 1588, 10/100 Base TX* + Redundant 100 Base TX
PRP, HSR, RSTP, 1588, 10/100 Base TX* + Redundant 100 Base TX
F650 DIGITAL BAY CONTROLLER
2.5 TECHNICAL SPECIFICATIONS
2-25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents