3.1 ENERVISTA 650 SETUP SOFTWARE

3.1.8 Actual values menu

The menu bar in the main screen of EnerVista 650 Setup software shows the ACTUAL menu option. This option
concentrates and displays all the status of protection, control elements, metering, counters information, oscillography,
events, fault locator, etc. This section shows only the structure of menus in EnerVista 650 Setup.
Actual

Front Panel

Status

Metering
Inputs/Outputs
Records
3.1.8.1 Front panel
The front panel menu shows the LEDs submenu where all the front LEDs can be monitored.
3.1.8.2 Status
The following menu includes all the available protection status in the device. Location of different menus can vary
depending firmware version.
status
Operation Bits
Breaker
Protection
Control Elements
Protection Summary
Snapshots Events
summary
ModBus User Map
Switchgear Status
Calibration
FlexCurves
System Info
Records Status
SNTP-IRIG_B & PTP
1588
Versions
Redundancy
3-28
The relay front LED status is shown on this menu.
Protection and control status signals for all available protection functions in device.
All metering values available in device. Primary and secondary values, frequency and
phasor diagram provided.
All input and output status provided. For contact inputs and contact outputs as well as
virtual input and virtual output signals.
Only enabled in online mode, retrieval of all the available records in device. Snapshot
events, control events, oscillography and fault reports.
Up to 24 elements. OPERATION BIT XX is (0) when the configured time out for the operation
XX expires or when success conditions are met. And it is (1) if operation XX is executed and
interlocks are fulfilled.
Breaker status (open, closed or undefined). The rest of the status signals corresponding to
the switchgear XX configured as breaker are in the Status > Switchgear Status >
Switchgear XX menu.
Status of all the protection units in the device.
Status of all the control units available in the device.
This screen shows a complete list of all protection and control elements in the relay,
showing their status (enabled or not).
Summary of the snapshot events status (enabled or disabled) for protection, control, inputs
and outputs boards and switchgear.
Up to 256 elements. Value in SIGNED INT 16 BIT format of the reading for the selected
address configured in Setpoint > Product Setup > ModBus User Map
Up to 16 blocks of switchgear status signals for the 16 configurable devices. Status signals
such as inputs for A and B contacts, status for A and B, open and close status, error 00 and
error 11, open init and close init, fail to open and fail to close signals.
Internal states for calibration. Factory calibration and calibration error signals.
Flex curve status for A, B, C and D user curves. (0) if it is not configured, (1) if it is configured.
To configure a flex curve go to Setpoint > System Setup > Flex Curves menu.
This screen can monitor the system parameters and the internal status of the Relay
operating system. Not enabled by default, password required
Information related to the different records stored in the Relay, such as: Fault reports,
control events, oscillography, data logger, demand, energy, and breaker maintenance.
Information related to synchronization via IRIG_B, SNTP or PTP1588.
Information related to the different firmware versions and hardware revisions.
Information related to the status of the frames sent through PRP and HSR. Also information
related to the status of RSTP port.