Power Requirements; Cpu Performance Specifications; Communications Support - GE PACSystems RXi User Manual

Distributed io controller
Table of Contents

Advertisement

1.1.4

Power Requirements

RXi Controller with IDM
RXI Controller with IDM and
Energy Pack
1.1.5

CPU Performance Specifications

Processor
Program storage
Non-volatile storage
Boolean execution speed, typical
Time of day clock (RTC) accuracy
Real Time Clock battery
Elapsed time clock (internal
timing) accuracy
Floating point
Program Blocks
Memory
1.1.6

Communications Support

Gigabit Ethernet Interface Specifications
Port connector
LAN
Number of IP addresses
User connections
Remote Station Manager
over UDP
Configurable Advanced User
Parameters
1
Refer to Appendix A, CPU Performance Data, for complete details.
GFK-2816F
1.5 A at 24Vdc (18–30 Vdc)
36 Watts minimum power supply recommended
3 A at 24Vdc (18–30 Vdc)
72 Watts minimum power supply recommended
1.0 GHz
10 MB of user memory and 10MB of user flash storage
Non-volatile storage (NVS) can retain data indefinitely without loss
of data integrity. An optional Energy Pack powers the CPU long
enough to write its user memory contents to non-volatile storage
during a system power loss.
Note:
To use the Energy Pack with the RXi Controller, you will
need controller firmware version 7.75 or later.
0.052 ms per 1000 Boolean instructions
Maximum drift of ±2 seconds/day at 25°C
Estimated life of 5 years; must be replaced every 5 years on a
regular maintenance schedule.
±0.01% maximum
64 bit
Up to 512 program blocks. Maximum size for a block is 128KB.
%I and %Q: 32Kbits for discrete
%AI and %AQ: configurable up to 32Kwords
%W: configurable up to the maximum available user memory
Symbolic: configurable up to the maximum available user memory
RJ-45 Port: 8-pin female shielded RJ-45 with 10/100/1000 Mbps
IEEE 802.2 Logical Link Control Class I
IEEE 802.3 CSMA/CD Medium Access Control 10/100 Mbps
One
Available through the front panel GbE port. Any given channel can
be assigned to only one protocol at a time.
47 maximum, shared among all supported protocols Includes:
A maximum of 16 Modbus/TCP Server connections
A maximum of 16 Modbus/TCP Client channels.
Monitor mode commands only. Refer to the PACSystems TCP/IP
Ethernet Communications Station Manager User Manual,
GFK-2225 for command operation.
Not supported in initial releases.
August 2015
Chapter 1. Introduction
1
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icrxictl000

Table of Contents