GE F650 User Manual page 206

Grid solutions digital bay controller
Hide thumbs Also See for F650:
Table of Contents

Advertisement

A.1 OPERANDS - F650 - MODEL FX - GX
OPERANDS - F650 - MODEL FX - GX
Internal System Status
IEC61850 Internal States
OTHER INTERNAL STATES (NON CRITICAL)
Other internal states
Autocheck Internal States (Not available)
A-2
ICD STATUS
USER MAP STATUS
FACTORY CALIBRATION
FLEXCURVE A STATUS
FLEXCURVE B STATUS
FLEXCURVE C STATUS
FLEXCURVE D STATUS
Green Zone
Yellow Zone
Orange Zone
Red Zone
UpTime
TIMER STATUS
GRAPHIC STATUS
ALARM TEXT ARRAY
F650 DIGITAL BAY CONTROLLER
UNKNOWN: when the relay has not the IEC61850
protocol in the relay model the ICD status is unknow to
the unit
ICD ERROR: There is an error in the ICD file and the
relay ICD is not operative. To solve this issue it is
necessary to send a correct ICD to the relay using the
IEC61850 configurator tool. When the ICD error is raised
the IEC 61850 will not be operative (the IEC 61850
client, reports and gooses will not work). It is advisable to
include the ICD ERROR in the main error signal
configured for specific applications.
MODIFIED: The settings have been changed in the icd
but they are still not written in the icd file in the relay
IN PROGRESS: The icd setting are being written to the
file in the relay
OK WITHOUT DAIS: The relay has not got the "Use DOI
&DAI" setting enabled (true) and it is working properly
with the ICD file.
OK: The relay has got the "Use DOI &DAI" setting
enabled (true) and it is working properly with the ICD file.
When that setting is set to true the icd setting prevails
over the relay settings.
User map status: (0) Not configured ; (1) Configured
Calibration status (0) Relay calibrated; (1) Not calibrated
User curve A: (0) Not configured (1) Configured
User curve B: (0) Not configured (1) Configured
User curve C: (0) Not configured (1) Configured
User curve D: (0) Not configured (1) Configured
Memory internal status
Memory internal status
Memory internal status
Memory internal status
System Time
Real time clock autocheck (not available)
Graphic display status (not available)
Text display status (not available)
APPENDIX A:
GEK-113000-AF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents