Danfoss VLT AutomationVTDrive FC322 Design Manual page 69

Hide thumbs Also See for VLT AutomationVTDrive FC322:
Table of Contents

Advertisement

3 VLT Automation VT Drive Selection
Data are measured according to IEC 60034-17.
Cable lengths are in metres.
FC322, P7K5T2
Cable
Mains
Rise time
length [m]
voltage [V]
[μsec]
5
230
0.13
3
50
230
0.23
100
230
0.54
150
230
0.66
FC322, P11KT2
Cable
Mains
length [m]
voltage [V]
Rise time [μsec]
36
240
0.264
136
240
0.536
150
240
0.568
FC322, P15KT2
Cable
Mains
Rise time
length [m]
voltage [V]
[μsec]
30
240
0.556
100
240
0.592
150
240
0.708
FC322, P18KT2
Cable
Mains
Rise time
length [m]
voltage [V]
[μsec]
36
240
0.244
136
240
0.568
150
240
0.720
FC322, P22KT2
Cable
Mains
Rise time
length [m]
voltage [V]
[μsec]
36
240
0.244
136
240
0.568
150
240
0.720
FC322, P30KT2
Cable
Mains
Rise time
length [m]
voltage [V]
[μsec]
15
240
0.194
50
240
0.252
150
240
0.488
68
MG.20.X1.22 - VLT
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20783-Danfoss-131X8145-VLT-Automation-VT-Drive-VFD-FC322-460V-.5-HP.aspx
Automation VT Drive FC322 Design Guide
Vpeak
dU/dt
[kV]
[kV/μsec]
0.510
3.090
2.034
0.580
0.865
0.560
0.674
Vpeak
[kV]
dU/dt [kV/μsec]
0.624
1.890
0.596
0.889
0.568
0.800
Vpeak
dU/dt
[kV]
[kV/μsec]
0.650
0.935
0.594
0.802
0.587
0.663
Vpeak
dU/dt
[kV]
[kV/μsec]
0.608
1.993
0.580
0.816
0.574
0.637
Vpeak
dU/dt
[kV]
[kV/μsec]
0.608
1.993
0.580
0.816
0.574
0.637
Vpeak
dU/dt
[kV]
[kV/μsec]
0.626
2.581
0.574
1.822
0.538
0.882
®
is a registered Danfoss trademark