Motion Features; Motionless Timeout - Wasp WDI4600 Product Reference Manual

1d 2d digital scanner usb
Hide thumbs Also See for WDI4600:
Table of Contents

Advertisement

References

Motion Features

Motionless Timeout

This setting specifies the amount of time that the reader takes to assume that it is in a motionless
condition. The range for this setting is from 500 msec to 25.5 seconds, in 100 millisecond
increments.
Follow these instructions to set this feature.
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0.5 = 0005 = 00, 5 =
3. Go to
4. Scan the barcode: SELECT MOTIONLESS TIMEOUT SETTING.
5. Scan the appropriate three digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See
Table 45. Motionless Timeout Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 100 (and pad with
2
leading zeroes to yield two
digits)
3
4
Scan Two Characters From
5
Appendix D, Keypad
6
236
050, 20 = 200, etc.
page 204
and scan the ENTER/EXIT PROGRAMMING MODE barcode to
enter Programming Mode.
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
Mode.
500ms
005
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT MOTIONLESS TIMEOUT SETTING
'0' , '0' and '5'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix D, Keypad
Table 45
for examples of how to set this feature.
EXAMPLES
1 sec.
010
'0' , '1' and '0'
'1' , '0' , and '0'
representing
10 sec
9,900ms (9.9 sec.)
100
250
'2' , '5' , and '0'