References
Disable Character
Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
To set the value:
1. Determine the desired character or value. A setting of 0xFF indicates the Disable Charac-
2. Use the
3. Go to
4. Scan the barcode: SELECT DISABLE CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See
Table 30. Disable Character Setting Examples
STEP
ACTION
1
Desired character/value
Hex equivalent from
2
Chart
3
4
Scan Two Characters From
5
Appendix D, Keypad
6
212
Setting to previously defined characters such as XON, XOFF, or host com-
mands conflicts with normal operation of these characters. 8-bit data is
not recognized when the option
ter is not used (not available).
ASCII Chart
on the inside back cover of this manual to find the hex equivalent
for the desired character/value.
page 30
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
pad, that represent the desired character/value in step 1 above. The second character will
cause a two-beep indication.
Mode.
'd'
ASCII
0x64
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT DISABLE CHARACTER VALUE SETTING
'6' and '4'
Scan ENTER/EXIT PROGRAMMING MODE
Data Bits
Table 30
for some examples of how to set this feature.
EXAMPLES
'}'
0x7D
'7' and 'D'
has been set as 7 Data Bits.
Appendix D, Key-
Disable Command
'D'
Not Used
0x44
0xFF
'4' and '4'
'F' AND 'F'
WDI4600