Flash On Time - Wasp WDI4600 Product Reference Manual

1d 2d digital scanner usb
Hide thumbs Also See for WDI4600:
Table of Contents

Advertisement

References

Flash On Time

This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with
3. Go to
4. Scan the barcode: SELECT FLASH ON TIME SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See
Table 41. Flash On Time Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 100 (and pad with
2
leading zeroes to yield two
digits)
3
4
Scan Two Characters From
5
Appendix D, Keypad
6
232
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
page 70
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
Mode.
500ms
05
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT FLASH ON TIME SETTING
'0' and '5'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix D, Keypad
Table 41
for examples of how to set this feature.
EXAMPLES
1,000ms (1 sec.)
5200ms (5.2 sec.)
10
'1' and '0'
representing the
9,900ms (9.9 sec.)
52
99
'5' and '2'
'9' and '9'
WDI4600

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents