Read Serial Number; Read Camera Version; Read Eeprom Firmware Version - Basler A202K Manual

Hide thumbs Also See for A202K:
Table of Contents

Advertisement

4.2.5.4 Read Serial Number

Purpose:
Type:
Read Command:
Response:
Data Format:

4.2.5.5 Read Camera Version

Purpose:
Type:
Read Command:
Response:
Data Format:

4.2.5.6 Read EEPROM Firmware Version

Purpose:
Type:
Read Command:
Response:
Data Format:
k
BASLER A202
To read the camera's serial number.
This is a read only command.
Cmd-ID
0x04
Cmd-ID
0x04
Zero terminated string if less than 16 bytes are needed for the serial number
information. Unterminated string if all 16 bytes are needed.
To read the camera's version information.
This is a read only command.
Cmd-ID
0x05
Cmd-ID
0x05
Byte 1
Byte 2
Byte 3
To read the EEPROM firmware version information.
This is a read only command.
Cmd-ID
0x06
Cmd-ID
0x06
Byte 1
Byte 2
Byte 3
DRAFT
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
Low Byte of camera's version
High Byte of camera's version
Register Layout ID
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
Low byte of firmware version
High byte of firmware version
Register Layout ID
Configuring the Camera
Data
16
-
Data
16
16 Bytes
Data
3
-
Data
3
3 Bytes
BCD coded
BCD coded
Data
3
-
Data
3
3 Bytes
BCD coded
BCD coded
4-21