Ethernet Connection; System Configuration - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal microcomputers, modbus/fieldbus products, peripherals
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

12.3 Ethernet Connection

12.3.1 System Configuration

When using the Ethernet connection cable
PC
Personal computer
• 100BASE-TX
Shielded twisted pair cable (STP)
or unshielded twisted pair cable
To be selected by the
(UTP) of category 5 or higher
user.
• 10BASE-T
Shielded twisted pair cable (STP)
or unshielded twisted pair cable
(UTP) of category 3 or higher
*1
*2
*3
12 - 8
12. PC REMOTE CONNECTION
12.3 Ethernet Connection
Connection cable
*1*2
Connection cable
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, wireless LAN adapter (NZ2WL-JPA or NZ2WL-JPS), or other system
equipment corresponding to the applicable Ethernet network system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
For the controllers that can be connected to the wireless LAN adapters and how to set the wireless LAN adapter, refer to the
manual of the wireless LAN adapter used.
A straight cable is available.
When connecting the GOT and PC directly with Ethernet cable, remember that the by cross cable is available.
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
Extended function OS
PC remote operation
(Ethernet)
GOT
Varies according to the
connection type.
Maximum
GOT
segment
Option device
*3
length
100m
- (Built into GOT)
Communication driver
Communication driver
Connection type
Ethernet system
dependent
PLC
PLC
Model
For the system
configuration between
the GOT and PLC,
refer to each chapter.
Number of
connectable
equipment
1 personal
computer for 1
GOT