(8) Sum check code
The sum check code is obtained by converting the lower 1 byte (8 bits) of the result (sum), after having added
the sum check target data as binary data, to 2-digit ASCII code (Hex).
STX
02
H
52
Command
Address
R
D
0
1
0
0
52
44
30
31
30
30
H
H
H
H
H
H
(H)
(L)
(H)
(L)
Sum check is performed in this range.
+ 44
+ 30
+ 31
+ 30
+ 30
+ 30
H
H
H
H
H
H
2. MICROCOMPUTER CONNECTION (SERIAL)
Sum
Number of
ETX
points
Check
0
2
B
C
30
32
03
42
43
H
H
H
H
H
(H)
(L)
(H)
(L)
+ 32
+ 03
= 1BC
H
H
H
H