*2
The write specification specifies how the data of the specified address is changed in the bit pattern.
2 - 74
2. MICROCOMPUTER CONNECTION (SERIAL)
2.5 Message Formats
Write
Function
specification
ON
0
Bits set to "1" by the bit pattern are turned ON.
specification
OFF
1
Bits set to "1" by the bit pattern are turned OFF.
specification
Invert
2
Bits set to "1" by the bit pattern are inverted.
specification
Write
The numerical values to write by the bit pattern are specified
3
specification
directly.
Description
Action example
Original data
1010
Bit pattern
1100
Result
1110
Original data
1010
Bit pattern
1100
Result
0010
Original data
1010
Bit pattern
1100
Result
0110
Original data
1010
Bit pattern
1100
Result
1100