Connection Diagram; Cable - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal microcomputers, modbus/fieldbus products, peripherals
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

11.3 Connection Diagram

The following diagram shows the connection between the
GOT and the barcode.
11.3.1
RS-232 cable
Connection diagram
(1) RS-232 connection diagram 1)
GOT side
(terminal block)
N.C.
RD
SD
ER
SG
DR
RS
CS
N.C.
Precautions when preparing a cable
(1) Cable length
The length of the RS-232 cable must be 15m or less.
(2) GOT side connector
For the GOT side connector, refer to the following.
1.4.1 GOT connector specifications
11 - 4
11. BAR CODE READER CONNECTION
11.3 Connection Diagram
Barcode side
(D-Sub 9 pin)
N.C.
1
RD(RXD)
2
SD(TXD)
3
ER(DTR)
4
SG
5
DR(DSR)
6
RS(RTS)
7
CS(CTS)
8
-
9

Advertisement

Table of Contents
loading

Table of Contents