2.4 Device Data Area

The following shows a list of virtual devices inside the GOT available in the microcomputer connection (serial), and the
address specification values for each data format.
The address specification of the virtual devices differs depending on the data format.
Virtual device
Device
Model
Name
range
(decimal)
D
0 to 4095
R
0 to 4095
L
0 to 2047
M
0 to 2047
SD
0 to 15
SM
0 to 63
D
0 to 4095
R
0 to 4095
L
0 to 2047
M
0 to 2047
SD
0 to 15
SM
0 to 63
*1
For the address specification method for each data format, refer to the following.
• Formats 1, 2
• Formats 3 to 6
• Formats 7 to 10
• Formats 11 to 13 : Digital Electronics Corporation's memory link method
• Formats 14, 15
*2
When reusing GOT900 Series project data
• GOT-A900 Series virtual devices (D0 to 2047)
• GOT-F900 Series virtual devices
*3
Access to SD3 to 9 can also be made by the specification of the addresses (3000 to 300D
POINT
POINT
POINT
Values of virtual devices inside the GOT
When the GOT is turned OFF or reset, values are cleared to their defaults
(bit devices: OFF, word devices: 0).
Values are held in the memory when project data are written to the GOT.
2 - 12
2. MICROCOMPUTER CONNECTION (SERIAL)
2.4 Device Data Area
*2
Device
Format
type
1, 2
Word
0 to 4095
Word
4096 to 8191
Bit
8192 to 8319
Bit
8320 to 8447
Word
8448 to 8463
Bit
8464 to 8467
Word
0 to 4095
Word
4096 to 8191
Bit
8192 to 8319
Bit
8320 to 8447
Word
8448 to 8463
Bit
8464 to 8467
2.5 Message Formats
: GOT-A900 Series microcomputer connection
: A compatible 1C frame
: QnA compatible 3C/4C frame
: GOT-F900 Series microcomputer connection
Can be used as they are without changing the assignments.
Since some of the assigned virtual device values differ as indicated below, change the assignment using device batch edit of
GT Designer3.
Refer to the following manual for device batch edit of GT Designer3.
GT Designer3 (GOT2000) Help
GOT1000 Series virtual devices
D0 to 2047
D2048 to 4095
R0 to 4095
L0 to 2047
M0 to 2047
SD0 to 15
SM0 to 63
Address specification value
Format
Format
3 to 6
7 to 10
D0 to 4095
D0 to 4095
0000 to 0FFF
R0 to 4095
R0 to 4095
1000 to 1FFF
L0 to 2047
L0 to 2047
2000 to 207F
M0 to 2047
M0 to 2047
2080 to 20FF
D9000 to
SD0 to 15
2100 to 210F
9015
M9000 to
SM0 to 63
2110 to 2113
9063
-
-
0000 to 0FFF
-
-
1000 to 1FFF
-
-
2000 to 207F
-
-
2080 to 20FF
-
-
2100 to 210F
-
-
2110 to 2113
GOT-F900 Series virtual devices
*1
Format
Format
11 to 13
14, 15
8000 to 9FFF
H
H
0000 to 1FFF
H
H
A000 to A0FF
H
H
2000 to 20FF
H
H
2100 to 211F
H
H
(3000 to 300D
)
H
2200 to 2207
H
H
8000 to 9FFF
H
H
0000 to 1FFF
H
H
A000 to A0FF
H
H
2000 to 20FF
H
H
2100 to 211F
H
H
(3000 to 300D
)
H
2200 to 2207
H
H
D0 to 4095
M0 to 2047
D8000 to 8015
GD0 to 6
M8000 to 8063
) of GD0 to 6 on the GOT-F900 Series.
H
Refer to
2.4.1
2.4.2
2.4.3
2.4.4
2.4.5
*3
2.4.6
2.4.1
2.4.2
2.4.3
2.4.4
2.4.5
*3
2.4.6

Advertisement

Table of Contents
loading