(7) Year, month, day, hour, minute, second and day of the week data
Specifies year, month, day, hour, minute, second, and day of the week to be read/set to the GOT clock data.
The address notated in decimal is converted to a 2-digit ASCII code (Hex) and transmitted from the upper digit.
■ Message format (1) Read clock data (1901) command
■ Message format (2) Set clock data (0901) command
(8) Error code
This is the response message at faulty communication appended with error contents.
The address notated in hexadecimal is converted to a 4-digit ASCII code (Hex) and transmitted from the upper
digit.
For details of error codes that are generated in formats 7 to 10 (QnA compatible 3C/4C frame), refer to the
following:
■ Error code list
POINT
POINT
POINT
When connecting a microcomputer, etc. that uses the MC protocol of the Q/QnA series serial communication
module with the GOT
When connecting a microcomputer, etc. that uses the MC protocol of the Q/QnA series serial communication
module with the GOT, correct the commands to be used and the device ranges to match the GOT specifications.
2. MICROCOMPUTER CONNECTION (SERIAL)
2.5 Message Formats
2
2 - 51