Title
f910
Step-out detection current level
f911  Step-out detection time
q-axis inductance
f912
f913  d-axis inductance
 Factory specific coefficient 9L
 Refer to section 6.25.2 about setting motor constants.
Note 1: When using an PM motor, consult your Toshiba distributor, since the inverter is not compatible with all
types of PM motors.
Note 2: The inverter may fail to detect step-out in some cases, because it uses an electrical method to detect
step-out. To avoid detection failures, you are recommended to install a mechanical step-out detector.

6.40 Traverse function

f980 : Traverse selection
f981 : Traverse acceleration time
f982 : Traverse deceleration time
f983 : Traverse step
f984 : Traverse jump step
 Refer to "Traverse control Instruction Manual : E6581877" for details.
Function
1 - 150 (%)
0.00: No detection
0.01 - 2.55 (s)
0.01-650.0 (mH)
0.01-650.0 (mH)
-
F-147
Adjustment range
Default setting
E6582175
100
0.00
10.00
10.00
-
6