Set parameters by purpose (Guidance function) auf
Only parameters required for a special purpose can be called up and set.
To use this function, select parameter auf
 Refer to section 6.1.3 for details.
Reset parameters to default settings typ
Use the typ parameter to reset all parameters back to the default settings. To use this function, set parameter
typ =3 or 13.
 Refer to section 4.3.2 for details.
4
Call saved customer settings 
Customer settings can be batch-saved and batch-called.
These settings can be used as customer-exclusive default settings.
To use this function, set parameter typ =7 or 8.
 Refer to section 4.3.2 for details.
Search changed parameters gru
Automatically searches for only those parameters that are programmed with values different from the default setting.
To use this function, select the gru parameter.
 Refer to section 4.3.1 for details.
4.3.1
gru : Automatic edit function
• Function
Automatically searches for only those parameters that are programmed with values different from the default
setting and displays them in the gru. Parameter setting value can also be changed while searching.
Note 1: If you reset a parameter to its factory default, the parameter will no longer appear in gru.
Note 2: It may take several seconds to display changed parameters because all data stored in gru is checked
against the default settings. To cancel a parameter search, press the MODE key.
Note 3: Parameters which cannot be reset to the default setting after setting typ to 3 are not displayed.
 Refer to section 4.3.2 for details.
Searching for and resetting changed parameters