Toshiba Tosvert VF-S15 Instruction Manual page 329

Industrial inverter
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

 Communication parameters
Communication
Title
No.
0800

0801

0802

0803

0804

0805

0806

0808

0810

0811

0812

0813

0814

11
Minimum
setting unit
Function
Unit
Panel/Commun
ication
Baud rate
-
Parity
-
Inverter number
-
1/1
Communication
s
0.1/0.1
time-out time
Communication
-
time-out action
Communication
s
0.01/0.01
waiting time
Setting of master
-
and slave for
communication
between inverters
Communication
-
time-out detection
condition
Communication
-
1/1
command point
selection
Communication
%
1/1
command point 1
setting
Communication
Hz
0.1/0.01
command point 1
frequency
Communication
%
1/1
command point 2
setting
Communication
Hz
0.1/0.01
command point 2
frequency
Adjustment range
-
3: 9600bps
4: 19200bps
5: 38400bps
-
0: No parity
1: Even parity
2: Odd parity
0-247
0.0: Disabled,
0.1-100.0
-
0: Alarm only
1: Trip (Coast stop)
2: Trip (Deceleration stop)
0.00-2.00
-
0: Slave (0 Hz command issued in
case the master inverter fails)
1: Slave (Operation continued in case
the master inverter fails)
2: Slave (Emergency stop tripping in
case the master inverter fails)
3: Master (transmission of frequency
commands)
4: Master (transmission of output
frequency signals)
-
0: Valid at any time
1: Communication selection of
fmod or cmod
2: 1 + during operation
0: Disabled
1: Enabled
0-100
0.0-
0-100
0.0-
K-30
E6582175
Default
User
Reference
setting
setting
4
6.38.1
1
0
0.0
0
0.00
0
1
0
6.10.2
6.38.1
0
0.0
100
*1