Toshiba Tosvert VF-S15 Instruction Manual page 25

Industrial inverter
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

1.3.3
Power circuit and control circuit terminal blocks
1) Power circuit terminal
In case of the crimp-style terminal, cover the crimp-style terminal with insulating tube, or use the crimp-
style terminal with insulation sleeve.
Refer to section 2.3.1 for details about terminal functions.
Screw Size
M3.5
M4
M5
M6
M4 (grounding terminal)
M5 (grounding terminal)
Note1) xxx means wire sizes. For the wire sizes, refer to the table in section 10.1
VFS15-2004PM-W1 to 2007PM-W1
Shorting-bar
Grounding terminal
(M4 screw)
Note1) Bend the clips on the wiring port of the terminal cover to connect the PB, PO, PA/+, and PC/- terminals.
Note2) Be careful to insert all wires into the cage of terminal block.
Crimp-style
terminal
Note1)
xxx – 3.5
xxx – 4
xxx – 5
xxx – 6
xxx – 4
xxx – 5
M3.5 screw
Grounding terminal
For EMC plate
(M5 screw)
A-13
Tightening torque
1.0 N  m
8.9 lb  in
1.4 N  m
12.4 lb  in
2.4 N  m
20.8 lb  in
4.5 N  m
40.0 lb  in
1.4 N  m
12.4 lb  in
2.8 N  m
24.8 lb  in
Grounding terminal
(M4 screw)
E6582175
1