Toshiba Tosvert VF-S15 Instruction Manual page 256

Industrial inverter
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

<Broadcast communication>
6
When sending an operation frequency command via a broadcast from the host computer
Host computer
INV
INV
No.00
No.01
INV= inverter
● : Split the cable among terminal blocks.
(1)
Send data from the host computer.
(2)
The inverters receive data from the host computer and the inverter number is checked.
(3)
When * is next to the position of an inverter number, it is judged a broadcast. The command is
decoded and processed.
(4)
To prevent data conflicts, only inverters where * is overwritten to 0 can reply with data to the host
computer.
(5)
As a result, all inverters are operating with the broadcast operation frequency command.
Note: Specify inverter numbers by group for group broadcasts.
(Function only for ASCII mode. For parity mode, see the Communications Function Instruction Manual.)
(Ex) When *1 is set, inverters 01, 11, 21, 31 to 91 can be broadcast to.
In this case, the inverter specified in 01 can reply.
: Wiring
: Data (Host  INV)
: Response data (INV  Host)
INV
INV
No.02
No.03
F-144
E6582175
INV
INV
No.29
No.30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents