Toshiba Tosvert VF-S15 Instruction Manual page 273

Industrial inverter
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

7.3.2
You can set the frequency settings by inputting an analog current signal of 4 (0) to 20mA dc between the VIC and
CC terminals.
The following shows examples when the run command is input from the terminal.
Title

Command mode selection
Frequency setting mode

selection 1
VIC input point 1 setting

VIC input point 1 frequency

VIC input point 2 setting

VIC input point 2 frequency

Analog input filter

*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
MCCB
Power
Supply
* Connect a single-phase
input model to R/L1 and
7
S/L2/N.
Settings depending on current (4 to 20 mA) input
Function
0 – 4
0 – 14
0 – 100%
0.0 - 500.0Hz
0 – 100%
0.0 - 500.0Hz
2 - 1000 ms
U/T1
R/L1
VF-S15
V/T2
S/L2
W/T3
T/L3
FLA
F
FLB
R
FLC
RES
S1
S2
S3
CC
CC
VIC
PP
+
4 (0) to 20 mA dc
-
Adjustment range
Default setting
(panel keypad)
(setting dial 1)
 Run and stop settings
You can switch between forward run (F) and
Motor
reverser run (R), and run/stop with external
M
signals.
 Setting characteristics for the current input
signal and frequency
Set characteristics at two points.
Forward
run
Reverse
run
Hz


0% 20%
(0mA) (4mA)
Current input signal
G-14
E6582175
Setting example
1
0
(terminal block)
0
8
(terminal VIC)
20
20 (or 0)
0.0
0.0
100
100
*1
50.0/60.0
64
64
Point 2
Point 1
%


100%
(20 mA)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents