Toshiba Tosvert VF-S15 Instruction Manual page 343

Industrial inverter
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

 Table of output terminal functions 3
Function
Code
No.
92
DATA1
93
DATA1N
94
DATA2
95
DATA2N
106
LLD
107
LLDN
108
HLD
109
HLDN
120
LLS
121
LLSN
122
KEB
123
KEBN
124
TVS
125
TVSN
126
TVSD
127
TVSDN
128
LTA
129
LTAN
130
POT
131
POTN
132
FMOD
133
FMODN
136
FLC
137
FLCN
138
FORCE
11
139
FORCEN
140
FIRE
141
FIREN
Function
Designated data output 1
Inversion of designated data output 1
Designated data output 2
Inversion of designated data output 2
Light load output
Inversion of light load output
Heavy load output
heavy load output
Inversion of
Lower limit frequency stop
Inversion of lower limit frequency stop
Power failure synchronized operation
Inversion of power failure synchronized
operation
Traverse in progress
Inversion of traverse in progress
Traverse deceleration in progress
Inversion of traverse deceleration in
progress
Parts replacement alarm
Inversion of parts replacement alarm
Over-torque detection pre-alarm
Inversion of over-torque detection pre-alarm
Frequency setting mode selection 1/2
Inversion of frequency setting mode
selection 1/2
Panel / remote selection
Inversion of panel / remote selection
Forced continuous operation in progress
Inversion of forced continuous operation in
progress
Specified frequency operation in progress
Inversion of specified frequency operation in
progress
Action
ON: bit0 of FA50 is ON
OFF: bit0 of FA50 is OFF
Inversion of DATA1
ON: bit1 of FA50 is ON
OFF: bit1 of FA50 is OFF
Inversion of DATA2
ON: Less than heavy load torque (f335~f338)
OFF: heavy load torque (f335~f338) or more
Inversion of LLD
ON: Heavy load torque (f335~f338) or more
OFF: Less than heavy load torque (f335~f338)
Inversion of HLD
ON: Lower limit frequency continuous operation
OFF: Other than those above
Inversion of LLS
ON: Power failure synchronized operation
OFF: Other than those above
Inversion of KEB
ON: Traverse in progress
OFF: Other than those above
Inversion of TVS
ON: Traverse deceleration in progress
OFF: Other than those above
Inversion of TVSD
ON: Any one of cooling fan, control board capacitor, or main
circuit capacitor reaches parts replacement time
OFF: Any one of cooling fan, control board capacitor, or main
circuit capacitor does not reach parts replacement time
Inversion of LTA
ON: Torque current is 70% of f616 setting value or more
OFF: Torque current is less than f616x70%-f619
Inversion of POT
ON: Select frequency setting mode selection 2 (f207)
OFF: Select frequency setting mode selection 1 (fmod)
Inversion of FMOD
ON: Operation command or panel
OFF: Other than those above
Inversion of FLC
ON: Forced continuous operation in progress
OFF: Other than those above
Inversion of FORCE
ON: Specified Frequency operation in progress
OFF: Other than those above
Inversion of FIRE
K-44
E6582175
Reference
6.38
6.21
6.13
6.19.2
6.40
6.29.15
6.29.10
5.8
6.2.1
6.30