7.3.1
Settings depending on voltage (0 to 10 V) input
<external potentiometer>
You can set the frequency settings by connecting the external potentiometer (1k to 10kΩ) between PP, VIA, and
CC terminals.
You can also set by inputting an analog voltage signal of 0 to 10Vdc between the VIA and CC terminals.
The following shows examples when the run command is input from the terminal.
Title
Function
 Command mode selection
Frequency setting mode

selection 1
Analog/logic input selection

(VIA/VIB)
 VIA input point 1 setting
 VIA input point 1 frequency
 VIA input point 2 setting
 VIA input point 2 frequency
 Analog input filter
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
MCCB
R/L1
Power
S/L2
Supply
T/L3
* Connect a single-phase
input model to R/L1 and
S/L2/N.
FLA
FLB
FLC
CC
Adjustment range
0 - 4
0 - 14
0 - 4
0 - 100%
0.0 - 500.0Hz
0 - 100%
0.0 - 500.0Hz
2 - 1000 ms
Motor
U/T1
M
VF-S15
V/T2
W/T3
Forward
run
F
Reverse
R
run
RES
S1
S2
S3
CC
VIA
PP
G-13
Default setting
Setting example
1
(panel keypad)
(terminal block)
0
(setting dial 1)
(terminal VIA)
0
(Analog input)
0
0.0
100
*1
64
 Run and stop settings
You can switch between forward run (F)
and reverser run (R), and run/stop with
external signals.
 Setting characteristics for the voltage
input signal and frequency
Set characteristics at two points.
Hz

Point 1



0%
100%
(0V)
(10 V)
Voltage input signal
E6582175
0
1
0 or 1
0
0.0
100
50.0/60.0
64
7
Point 2
%