Toshiba Tosvert VF-S15 Instruction Manual page 320

Industrial inverter
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

Communication
Title
Function
No.
0625
Factory specific

coefficient 6A
0626
Over-voltage stall

protection level
0627
Undervoltage

trip/alarm
selection
0629
Factory specific

coefficient 6B
0631
Inverter overload

detection method
0632
Electronic-thermal

memory
0633
Analog input break

detection level (VIC)
0634
Annual average

ambient
temperature (parts
replacement
alarms)
0642
Factory specific

coefficient 6G
0643
Factory specific

coefficient 6C
0644
Operation

selection of
analog input break
detection (VIC)
0645
PTC thermal

selection
0646
PTC detection

resistor value
0648
Number of starting

alarm
0649
Fallback frequency

0650
Forced fire-speed

control selection
0656
Factory specific

coefficient 6D
0657
Overload alarm level

0660
Override addition

input selection
0661
Override

multiplication input
selection
*2: Default setting values vary depending on the capacity. Refer to section 11.4.
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
-
-
-
%
1/1
100-150
-
-
0: Alarm only(detection level 60% or less)
1: Tripping (detection level 60% or less)
2: Alarm only(detection level 50% or
less, input AC or DC reactor required)
3: -
-
-
-
-
-
0: 150%-60s (120%-60s)
1: Temperature estimation
-
-
0: Disabled (thr, f173)
1: Enabled (thr, f173)
2: Disabled (thr)
3: Enabled (thr)
%
1/1
0: Disabled,
1-100
-
-
1: -10 to +10C
2: 11-20C
3: 21-30C
4: 31-40C
5: 41-50C
6: 51-60C
-
-
-
-
-
-
-
-
0: Tripping
1: Alarm only (Coast stop)
2: Alarm only (f649 frequency)
3: Alarm only (Maintain running)
4: Alarm only (Deceleration stop)
-
-
1: Tripping
2: Alarm only
Ω
1/1
100-9999
10000
0.1/0.1
0.0-999.0
times
Hz
0.1/0.01
ll-
-
-
0: Disabled
1: Enabled
-
-
-
%
1/1
10-100
-
-
0: Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4: fc
-
-
0: Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4: f729
K-21
E6582175
Default
User
Reference
setting
setting
-
*3
*2
6.19.4
6.19.5
0
6.29.13
-
* 3
0
5.6
0
5.6
6.29.1
0
6.29.14
3
6.29.15
-
*3
-
0
6.29.14
1
6.29.16
3000
999.0
6.29.17
0.0
6.29.14
0
6.30
-
* 3
50
5.6
0
6.31
0
11

Hide quick links: