Toshiba Tosvert VF-S15 Instruction Manual page 150

Industrial inverter
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

[Parameter setting]
Title
f107
f109
f201 VIA input point 1 setting
f202 VIA input point 1 frequency
f203 VIA input point 2 setting
f204 VIA input point 2 frequency
f209 Analog input filter
f210 VIB input point 1 setting
f211 VIB input point 1 frequency
6
f212 VIB input point 2 setting
f213 VIB input point 2 frequency
f216 VIC input point 1 setting
f217 VIC input point 1 frequency
f218 VIC input point 2 setting
f219 VIC input point 2 frequency
f810
f811
f812
f813
f814
*1: Default setting values vary depending on the setup menu. Refer to section 11.5.
Note 1: Do not set point 1 and 2 to the same value. If they are set to the same value, err1 is displayed.
Function
Analog input terminal
selection (VIB)
Analog/logic input
selection (VIA/VIB)
Communication command
point selection
Communication command
point 1 setting
Communication command
point 1 frequency
Communication command
point 2 setting
Communication command
point 2 frequency
F-38
Adjustment range
0: 0-+10V
1: -10-+10V
0: VIA - analog input
VIB - analog input
1: VIA - analog input
VIB - contact input
2: -
3: VIA - contact input (Sink)
VIB - contact input
4: VIA - contact input (Source)
VIB - contact input
0-100 (%)
0.0-500.0 (Hz)
0-100 (%)
0.0-500.0 (Hz)
2-1000 (ms)
-100-+100 (%)
0.0-500.0 (Hz)
-100-+100 (%)
0.0-500.0 (Hz)
0-100 (%)
0.0-500.0 (Hz)
0-100 (%)
0.0-500.0 (Hz)
0: Disabled
1: Enabled
0-100 (%)
0.0-fh (Hz)
0-100 (%)
0.0-fh (Hz)
E6582175
Default setting
0
0
0
0.0
100
*1
64
0
0.0
100
*1
0
0
100
*1
0
0
0
100
*1