 Acceleration/deceleration time parameters
Communication
Title
No.
0500

0501

0502

0503

0504

0505

0506

0507

0510

0511

0512

0513

0515

0519

*8: These parameters can be changed to 0.01s unit by setting f519=1.
11
Minimum
setting unit
Function
Unit
Panel/Commun
ication
Acceleration time 2
s
0.1/0.1
Deceleration time 2
s
0.1/0.1
Acceleration/decel
-
eration 1 pattern
Acceleration/decel
-
eration 2 pattern
Acceleration/decel
-
eration selection
(1, 2 , 3)
(Panel keypad)
Acceleration/decel
Hz
0.1/0.01
eration 1 and 2
switching
frequency
S-pattern lower-
%
1/1
limit adjustment
amount
S-pattern upper-
%
1/1
limit adjustment
amount
Acceleration time 3
s
0.1/0.1
Deceleration time
s
0.1/0.1
3
Acceleration/decel
-
eration 3 pattern
Acceleration/decel
Hz
0.1/0.01
eration 2 and 3
switching
frequency
Deceleration time
s
0.1/0.1
at emergency stop
Setting of
-
acceleration/decel
eration time unit
Adjustment range
0.0-3600 (360.0) *8
0.0-3600 (360.0) *8
-
0: Linear
1: S-pattern 1
2: S-pattern 2
-
-
1: Acceleration/deceleration 1
2: Acceleration/deceleration 2
3: Acceleration/deceleration 3
0.0 (disabled)
0.1-
0-50
0-50
0.0-3600 (360.0) *8
0.0-3600 (360.0) *8
-
0: Linear
1: S-pattern 1
2: S-pattern 2
0.0 (disabled)
0.1-
0.0-3600 (360.0) *8
-
0: -
1: 0.01s unit (after execution: 0)
2: 0.1s unit (after execution: 0)
K-18
E6582175
Default
User
Reference
setting
setting
10.0
6.27.2
10.0
0
6.27.1
0
6.27.2
1
0.0
10
6.27.1
10
10.0
6.27.2
10.0
0
0.0
10.0
6.29.4
0
5.2
6.27.2