Toshiba Tosvert VF-S15 Instruction Manual page 392

Industrial inverter
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

Table 3: Parameter default setting values for IE3 motor (V120 or later version defaults)
vb/
Type form
f172
%
VFS15-2004PM-W1
VFS15-2007PM-W1
4.8
VFS15-2015PM-W1
4.8
VFS15-2022PM-W1
3.1
VFS15-2037PM-W1
3.1
VFS15-2055PM-W1
2.5
VFS15-2075PM-W1
2.3
VFS15-2110PM-W1
1.8
VFS15-2150PM-W1
1.6
VFS15S-2002PL-W1
VFS15S-2004PL-W1
VFS15S-2007PL-W1
4.8
VFS15S-2015PL-W1
4.8
VFS15S-2022PL-W1
3.1
VFS15-4004PL-W1
VFS15-4007PL-W1
4.8
VFS15-4015PL-W1
4.8
VFS15-4022PL-W1
3.1
VFS15-4037PL-W1
3.1
VFS15-4055PL-W1
2.5
VFS15-4075PL-W1
2.3
VFS15-4110PL-W1
1.8
VFS15-4150PL-W1
1.6
*3: Refer to section 3.1 'How to Set the Setup Menu' and 4.4 'Checking the region settings selection'.
f402 f415 f416
%
A
%
Same values as Table 4 (V116 or earlier version)
4.3
3.40
55
4.4
6.40
42
2.9
9.40
50
2.8
14.60
38
2.3
21.40
41
2.0
28.60
38
1.6
42.00
38
1.5
55.60
33
Same values as Table 4 (V116 or earlier version)
4.3
3.40
55
4.4
6.40
42
2.9
9.40
50
Same values as Table 4 (V116 or earlier version)
4.3
1.70
55
4.4
3.20
42
2.9
4.70
50
2.8
7.30
38
2.3
10.70
41
2.0
14.30
38
1.6
21.00
38
1.5
27.80
33
S-4
f417
f417
f456 f457 f458 f459
(JP,USA)*3
(ASIA,EU)*3
-1
-1
min
min
%
1730
1440
1740
1445
1755
1460
120
1755
1460
1760
1465
1755
1460
1770
1475
1760
1470
1730
1440
120
1740
1445
1755
1460
1730
1440
1740
1445
1755
1460
1755
1460
120
1760
1465
1755
1460
1770
1475
1760
1470
E6582175
Times
50
101
1.5
50
101
1.5
50
101
1.5
17