10.8.5 Exit Switch-to-Duplex Failure

1 Check the Exit Assembly. The Exit Assembly functions correctly.
NOTE: Execute Diagnostic Mode 1, Exit Motor CW, and check if the Exit Motor rotates clockwise.
Y: Go to step 2.
N: Go to RAP 7.4.10 Exit Sensor Assembly Failure.
2 Check the Print Engine Controller. The "Exit Switch-to-Duplex Failure" occurs after the Print
Engine Controller was replaced.
Y: Check the System Controller PWB Assembly connection to the Print Engine Controller
PWB connection.
N: The problem is solved.