Exit Motor Ccw (Counter Clockwise) Operation - Olivetti DR N17 Service Manual

Table of Contents

Advertisement

5.2.1.16 Exit Motor CCW (Counter Clockwise) Operation

This diagnostic tests the Exit Motor counterclockwise function.
Execute Exit Motor CCW Operation:
1 Enter Diagnostics Mode 1. The LCD displays PRINT COUNTER OPERATION indicating the
printer is in Diagnostics Mode 1.
2 Press the MENU UP (1) or MENU DOWN (5) key until the LCD displays the EXIT MOTOR-CWW
OPERATION message.
3 Press the ENTER key to execute the test. The LCD displays the EXIT MOTOR-CWW
OPERATION message.
EXIT MOTOR-CCW
Operation EXECED
4 Verify that each time the ENTER key is pressed the Exit Motor rotates counter clockwise.
5 If you wish to exit this test and enter another test use the MENU UP (1) or MENU DOWN (5) key
to scroll to another test.
6 To exit this test and return to normal operation, switch OFF the printer power then switch it ON.
687200Q
Service Manual
5-45