7.3.16 "Install Print Cartridge" Message (J3)
1 Ensure the Print Cartridge interlock is functioning properly by doing the following:
Open the front cover and remove the print cartridge.
Ensure the projection on the Print Cartridge that activates the sensor is not damaged.
Use the Diagnostic Mode 1, Input Sensor Test and manually actuate and deactuate the print
cartridge interlock switch. The print cartridge sensor increments the Diagnostic Mode 1
counter.
Y:
Replace the Print Engine Controller.
N: Go to step 2.
2 Check for +5VDC at P/J111-A4 to A3. (For convenience, you can make this check at the Fuser
PWB P/J116-7 to P/J116-11.)
Y:
Go to step 6.
N: Go to step 3.
3 Check for +5VDC between P/J15-A9 and P/J15-A10.
Y:
Replace the Wire Harness between P/J15 and P/J111.
N: Go to step 4.
4 Check for +5VDC between P/J25-2 and P/J25-5.
Y:
Replace the Print Engine Controller.
N: Go to step 5.
5 Check for +5VDC between P/J12-2 and P/J12-5.
Y:
Replace the Wire Harness between P/J12 and P/J25.
N: Go to RAP 7.4.5 Low Voltage Power Supply (LVPS) Assembly Failure (+5VDC).
6 Check for +5VDC between P/J15 B9 (CRU SNR) and P/J15-A10 when the Print Cartridge is
removed and 0VDC when the print cartridge is installed.
Y:
Replace Print Engine Controller.
N: Go to step 7.
7 Check for +5VDC between P/J111-B4 and P/J111-A3.
Y:
Replace the Wire Harness between P/J111 and P/J15.
N: Replace the High Voltage Power Supply.
NOTE: Disconnect P/J12 and P/J15 from the Print Engine Controller and perform the analysis.
7-32