Centering (Duplex 2Nd Side) - Olivetti MB-502 Service Manual

Option printer
Table of Contents

Advertisement

5. Machine Adjustment
5.1.3

Centering (Duplex 2nd side)

NOTE
• Make this adjustment after any of the following procedures has been performed.
When the PH unit has been replaced.
The image on the backside of the 2-sided copy deviates in the main scan direction.
1. Call the Service Mode to the screen.
See P.146 of the main body service manual.
2. Touch [Machine Adjustment]
8. Produce another test print and check to see if width A falls within the specified range.
9. Touch [OK].
10. Touch [OK] on the Service Mode screen.
11. Turn OFF the main power switch, then wait for 10 sec. or more and turn ON the main
power switch.
16
[Printer Area]
A0EPF3E518DA
A
4061F3C809DA
Service Manual
Field Service Ver. 1.0 Jun. 2008
[Centering (Duplex 2nd side)].
3. Touch [Bypass Tray].
4. Press the Start key to let the
machine produce a test print.
5. Touch [OK].
6. Measure the width of printed refer-
ence line A.
Specification: 3.0 mm
7. If the measured width A falls outside
the specified range, enter the correc-
tion value using the [
key.
±
2.0 mm
] or [
]
Y109730-6

Advertisement

Table of Contents
loading