5.2.1 Diagnostic Mode 1
Table 5.2.1.1 lists the tests contained in Diagnostic Mode 1
Test Type
Total Print
Count
Input Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
Output Test
687200Q
Table 5.2.1.1 Diagnostic Mode 1 Tests
LCD Display Message
PRINT COUNTER
OPERATION
SENSOR INPUT TEST
READING FUSER
SET TEMPERATURE
READING FUSER
TEMPERATURE
CONFIRM MBF
SOLENOID OPERA
CONFIRM TRAY 1
SOLENOID OPERA
CONFIRM TRAY 2
SOLENOID OPERA
CONFIRM TRAY 3
SOLENOID OPERA
CONFIRM ENVELOPE
SOLENOID OPERA
CONFIRM DIRECT
SOLENOID OPERA
CONFIRM REG.
SOLENOID OPERA
MAIN MOTOR
OPERATION
DUPLEX MTR H.S.
OPERATION
DUPLEX MTR L.S.
OPERATION
EXIT MOTOR-CW
OPERATION
EXIT MOTOR-CCW
OPERATION
OCT DRIVE MOTOR
OPERATION
OFFSET MOTOR-CW
OPERATION
OFFSET MOTOR-CCW
OPERATION
Service Manual
Test Function
Shows the total number of prints made.
Tests a sensor or switch function.
Shows the Fuser temperature setting
(temperature code).
Shows the actual temperature of the
Fuser.
Tests the MBF Feed Solenoid function.
Tests the Tray 1 (top) Feed Solenoid
function.
Tests the Tray 2 (lower 1) Feed Solenoid
function.
Tests the Tray 3 (lower 2) Feed Solenoid
function.
Tests the Envelope Tray (optional) Feed
Solenoid function.
Tests the Exit Direction Solenoid
function.
Tests the Registration Solenoid
Tests the Main Motor function.
Tests the Duplex Motor function (high-
speed rotation).
Tests the Duplex Motor function (low-
speed rotation).
Tests the Exit Motor Clockwise (CW)
function.
Tests the Exit Motor Counter Clockwise
(CCW) function.
Tests the Offset Catch Tray (OCT) Motor
function.
Tests the Offset Motor Clockwise (CW)
function.
Tests the Offset Motor Counter Clock-
wise (CCW) function.