Henny Penny OFG-341 Operator's Manual
Henny Penny OFG-341 Operator's Manual

Henny Penny OFG-341 Operator's Manual

High volume open fryer
Hide thumbs Also See for OFG-341:

Advertisement

OPERATOR'S
M A N U A L
HIGH VOLUME OPEN FRYER
MODEL
OFE/OFG-341
OFE/OFG-342
OEA/OGA-341
OEA/OGA-342
R E G I S T E R W A R R A N T Y O N L I N E AT W W W. H E N N Y P E N N Y. C O M

Advertisement

Table of Contents
loading

Summary of Contents for Henny Penny OFG-341

  • Page 1 OPERATOR’S M A N U A L HIGH VOLUME OPEN FRYER MODEL OFE/OFG-341 OFE/OFG-342 OEA/OGA-341 OEA/OGA-342 R E G I S T E R W A R R A N T Y O N L I N E AT W W W. H E N N Y P E N N Y. C O M...
  • Page 3 Model OFE/OFG/OEA/OGA-341, 342 This manual should be retained in a convenient location for future reference. A wiring diagram for this appliance is located on the inside of the right side panel. Post in a prominent location, instructions to be followed in event user smells gas. This information shall be obtained by consulting the local gas supplier.
  • Page 4 Model OFE/OFG/OEA/OGA-341, 342 Technical Data for CE/AGA Marked Products Nominal Heat Input: Natural (I2H) = 31.7 kW (108,165 Btu/h) Natural (I2E) = 31.7 kW (108,165 Btu/h) (Net) Natural (I2E+) = 31.7 kW (108,165 Btu/h) Natural (I2L) = 31.7 kW (108,165 Btu/h) Natural (I2HS) = 31.7 kW (108,165 Btu/h) Liquid Propane (I3P) = 31.7 kW (108,165 Btu/h) Nominal Heat Input:...
  • Page 5: Table Of Contents

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 TABLE OF CONTENTS Section Page Section 1. INTRODUCTION ......................1-1 Introduction ....................1-1 Features......................1-1 Proper Care ....................1-1 Assistance ...................... 1-1 Safety ......................1-2 Section 2. INSTALLATION ......................2-1 Introduction ....................2-1 Unpacking...................... 2-1 Selecting Fryer Location ................
  • Page 6: Section 1. Introduction

    Model OFE/OFG/OEA/OGA-341, 342 SECTION 1. INTRODUCTION 1-1. INTRODUCTION The Henny Penny open fryer is a basic unit of food equipment designed to cook foods better and easier. The microcomputer based design helps make this possible. This unit is used only in institutional and commercial food service operations.
  • Page 7: Safety

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 1-5. SAFETY The Henny Penny open fryer has many safety features incorporated. However, the only way to ensure safe operation is to fully understand the proper installation, operation, and maintenance procedures. This appliance is not intended for use by persons (including...
  • Page 8: Section 2. Installation

    The Henny Penny open fryer has been tested, inspected, and expertly packed to ensure arrival at its destination in the best possible condition. The unit is banded to a wooden skid and then packed inside a heavy cardboard carton with sufficient padding to withstand normal shipping treatment.
  • Page 9: Leveling The Open Fryer

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 2-3. SELECTING THE Proper location of the open fryer is very important for operation, LOCATION speed, and convenience. Locate the open fryer to allow clearances for servicing and proper operation. Choose a location which provides easy loading and unloading without interfering with the final assembly of food orders.
  • Page 10: Gas Supply

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 2-5. VENTILATION OF FRYER (Continued) When installing the gas fry station do not attach an extension to the gas flue exhaust stack. This may impair proper operation of the burner, causing malfunctions and possible negative back draft. 2-6.
  • Page 11 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 For Australia or New Zealand: Where a model is supplied with castors and is to be connected to a fixed gas supply via a flexible hose connection, a re- straining chain or wire of adequate strength shall be fixed to the appliance and be suitable to be fixed to the wall within 50 mm of each connection point.
  • Page 12 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 2-6. GAS SUPPLY A standard one inch, black steel pipe and malleable • (Continued) fittings should be used for gas service connections. • Do not use cast iron fittings. • Although 1 inch (2.54 cm) sized pipe is recommend for 2 wells and 3/4 inch (1.9 cm) sized pipe is recommended for single wells, use adequate sized pipe and install properly, to provide a supply of gas...
  • Page 13: Gas Leak Test

    • Natural: 3.5 inches water column (8.7 mbar). • Propane 10.0 inches water column (24.9 mbar). The gas pressure regulator has been set by Henny Penny and is not to be adjusted by the user. 2-9. ELECTRICAL • 120 V, 60 Hz., 12 A, 1 PH REQUIREMENTS •...
  • Page 14: Electrical Requirements Ofe/Oea-340 Series

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 2-9. ELECTRICAL REQUIREMENTS OFG/OGA-340 SERIES (Continued) To avoid electrical shock, do not disconnect the ground (earth) plug. This fryer must be adequately and safely grounded. Refer to local electrical codes for correct grounding (Earthing) proceduresor in absence of local codes, with the National Electrical Code, ANSI/NFPA No.
  • Page 15: Additional Ce Electrical Statements

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 2-11. ADDITIONAL CE ELECTRICAL STATEMENTS • The supply power cords shall be oil-resistant, sheathed flexible cable, no lighter than ordinary polychloroprene or other equivalent synthetic elastomer-sheathed cord. • It is recommended that a 30 mA rated protective device such as a residual current circuit breaker (RCCB), or ground fault circuit interrupter (GFCI), be used on the fryer circuit.
  • Page 16: Section 3. Operation

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 SECTION 3. OPERATION 3-1. OPERATING Reference Figure 3-1. COMPONENTS C1000 CONTROLS Fig. Item Description Function Digital Display Shows the shortening temperature, the timer countdown in the Cook Cycle, and the selections in the Program Mode; the temperature of the shortening can be shown by pressing once, or twice to view set-point temperature;...
  • Page 17 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 Figure 3-1 April 2008...
  • Page 18 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-2. OPERATING This section provides operating procedures for the Henny Penny CONTROLS 12 340 series open fryer with 12 button timer controls. Read sections BUTTON CONTROLS 1, 2, and 3, and all instructions before operating the fryer.
  • Page 19 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-2. OPERATING CONTROLS 12 BUTTON CONTROLS (Continued) Fig. Item Description Function Used to access the Program Modes; once in the Program Mode, it is used to advance to the next parameter Used to stop Cook Cycles and also to stop the quality timer at the end of a Hold Mode;...
  • Page 20 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 Figure 3-2 Sept. 2003...
  • Page 21: Filling Or Adding Shortening

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-3. FILLING OR ADDING SHORTENING The shortening level must always be above the heating elements when the fryer is heating and at the frypot level indicators on the rear of the frypot. Failure to follow these instructions could result in a fire and/or damage to the fryer.
  • Page 22: C1000 Operations And Procedures

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-4. C1000 OPERATIONS The Computron 1000 controls are available on both split electronic AND PROCEDURES controls frypot and full frypot fryers. The following is a brief description of the operating procedures for fryers with these controls. Be sure the drain valve is in the closed position.
  • Page 23: C1000 Programming Instructions

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-4. C1000 OPERATIONS AND PROCEDURES (Continued) Do not overload, or place product with extreme moisture content into the basket. 12.5 lbs. (5.7 kg) is the maximum amount of product per frypot (6.25 lbs. (2.8 kg) maximum for the split frypot fryers). Failure to follow these directions can result in shortening overflowing the frypot.
  • Page 24: C1000 Special Programming

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-6. C1000 SPECIAL Special Programming is used to set the items below: PROGRAMMING • Fahrenheit or Celsius • Initialize System • Lock or Unlock Controls • Heat Source – Electric; Gas w/standing pilot; Gas w/electronic ignition; Gas-Induced Draft •...
  • Page 25: Basic Operations And Procedures (12 Product Controls/Auto-Lift)

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-7. BASIC OPERATIONS The Henny Penny open fryers are available with 12 product AND PROCEDURES button controls. Also, models OEA/OGA are available with 12 - (12 Button Controls/ button controls with auto-lift features. The auto-lift controls...
  • Page 26 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-7. BASIC OPERATIONS AND PROCEDURES - (12 Button Controls/ The two separate timer controls (left and right), can be Autolift) (Continued) programmed entirely independent from each other for 2 half baskets, or as one timer for a single, full sized basket.
  • Page 27 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-7. BASIC OPERATIONS AND PROCEDURES- (12 Button Controls/ To load product directly into the shortening on Auto- Autolift) (Continued) lift fryers, lower empty basket(s) into the shortening by pressing , load with product, then press the product button to start the Cook Cycle.
  • Page 28: Care Of Shortening

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-8. CARE OF SHORTENING FOLLOW THE INSTRUCTIONS BELOW TO AVOID SHORTENING OVERFLOWING THE FRYPOT, WHICH COULD RESULT IN SERIOUS BURNS, PERSONAL INJURY, FIRE, AND/OR PROPERTY DAMAGE. Maintain the shortening at the proper cooking level. Add fresh shortening as needed.
  • Page 29: Filtering Of Shortening

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-9. FILTERING OF Turn the main switch to the off position. Remove and SHORTENING clean the fry basket in soap and water. Rinse thoroughly. DRAIN VALVE HANDLE Best results are obtained when shortening is filtered at the normal frying temperature.
  • Page 30 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-9. FILTERING OF Rinse the frypot as follows: SHORTENING a. Close the drain valve. (Continued) b. Position return line over empty frypot. Figure 3-8. c. Move the pump switch to the pump position. d. Fill the frypot 1/3 full, then turn off pump. e.
  • Page 31: Filter Pump Problem Prevention

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-9. FILTERING OF SHORTENING (Continued) About 10 to 12 filterings can be made with one filter paper envelope, depending on: • the quantity and type of product fried and filtered • the type of breading used •...
  • Page 32: Changing The Filter Envelope

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-12. CHANGING THE Change the filter envelope after 10-12 filterings or whenever it FILTER ENVELOPE becomes clogged with crumbs. Proceed as follows: The filter union could be hot. Wear protective glove or cloth, or severe burns could result. Use care to prevent burns caused by splashing of hot shortening.
  • Page 33: Cleaning The Frypot(S)

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-12. CHANGING THE Fold the corners in and then double fold the open end. FILTER ENVELOPE (Continued) Clamp the envelope in place with the two filter retaining clips. Replace the crumb catcher screen on top of the filter paper.
  • Page 34 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-13. CLEANING Close the drain valve. Discard the shortening in the filter THE FRYPOT(S) pan using the shortening shuttle. Then install the filter drain (Continued) under the fryer, leaving out the filter screen assembly. The filter union could be hot.
  • Page 35: Clean-Out Mode

    Replace the clean filter screen assembly in the drain pan, replace cover, and install drain pan under fryer. Refill the frypot with fresh shortening. Henny Penny has the following cleaners available: Foaming Degreaser - Part no. 12226 PHT Liquid Cleaner - Part no. 12135 PHT Dry Powder Cleaner - Part no.
  • Page 36: Lighting And Shutdown Of The Burners

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-15. LIGHTING AND Turn the power switch to the OFF position. SHUTDOWN OF THE BURNERS Rotate the gas valve knob clockwise to the OFF position and wait at least five(5) minutes before continuing to the next step.
  • Page 37: Regular Maintenance

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 3-17. REGULAR As in all food service equipment, the Henny Penny open fryer MAINTENANCE requires care and proper maintenance. The table below provides a summary of scheduled maintenance procedures to be performed by the operator.
  • Page 38: Section 4. Programming

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 SECTION 4. PROGRAMMING 4-1. INTRODUCTION The controls are preset from the factory, but desired Functions can be programmed in the field. This section includes the Product Programming Mode, which are the basic settings, and the Level 2 programming, which are the more detailed settings.
  • Page 39 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-2. PRODUCT PROGRAM Press and hold to exit Program Mode, or press MODE (Continued) and release until “COOK” shows in display, to continue with Program Mode. Press and release and “COOK TIME” shows in the display along with the preset time.
  • Page 40 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 Press and release a fifth time and “LCOMP AVG” 4-2. PRODUCT PROGRAM MODE (Continued) shows in the display along with the load compensation average temperature. Press and release change this value to a maximum of 50°F (10ºC) below setpoint temperature.
  • Page 41: Special Program Mode

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-2. PRODUCT PROGRAM Filter Cycle Mode (Optional) MODE (Continued) For “2,MIXED”, or “3,GLOBAL” to appear in the Product Program Mode, the Filter Tracking must be enabled in the Special Program Mode.(See Special Program Mode Section) Press “2,MIXED”...
  • Page 42 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-3. SPECIAL PROGRAM Press and hold for 5 seconds until MODE (Continued) “L-2” and “LEVEL 2”, followed by, “SP PROG” and “ENTER CODE shows in the display. Enter code 1, 2, 3, and “SP- 1 “, “TEMP, UNITS” shows in the display.
  • Page 43 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-3. SPECIAL PROGRAM System Initialization (SP-3) MODE (Continued) This step resets the cook programs to factory settings. Follow steps 1and 2 above. Press and release twice. “SP-3” and “DO SYSTEM INIT” flashes on the display, along with “INIT’. Press and hold .
  • Page 44 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-3. SPECIAL PROGRAM Audio Effect (SP-6) MODE (Continued) This setting lets you add an “audio effect”- i.e. a pulsed or “warble,” sound effect – to the beeps generated in a Cook Cycle. Follow steps 1 and 2 above. Press 5 times.
  • Page 45 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-3. SPECIAL PROGRAM Idle Mode (SP-8) MODE (Continued) A programmed Idle Mode allows the shortening temperature to drop to a lower temperature when not in use. This saves on the shortening and utilities. Follow steps 1and 2 above. Press and release 7 times.
  • Page 46 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-3. SPECIAL PROGRAM To use the right product button 6 as the manual idle MODE (Continued) button, press . “SP-8C” and “USE-6R-FOR IDLE” shows in the display, along with “NO” or “YES”. Press to toggle between NO and YES. If “YES”...
  • Page 47 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-3. SPECIAL PROGRAM Press and “SP-9C” shows in the display, if YES MODE (Continued) was chosen in step e. FILTER LOCKOUT AT…” and a value between 100% and 200% shows in display. Press to change this value. Now, go back to the Product Program Mode, to the Filter Cycle, and program in the number of Cook Cycles between filtering.
  • Page 48 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-3. SPECIAL PROGRAM When using the first option, “1,COOK”, pressing a MODE (Continued) product button displays that and starts the Cook Cycle. When nothing is cooking, no product displays. Products 1 to 6 shows on the left display only, and products 7 to 12 shows on the right display only.
  • Page 49 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-3. SPECIAL PROGRAM Press to show the second option. “2,QT+ID”, MODE (Continued) sets the display to constantly show the Quality Time remaining, and the product ID that the Quality Time is holding after a Cook Cycle. The third option, “3,NM+QT”, sets the display to alternate between the name of the product just cooked and the Quality Time remaining.
  • Page 50 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4.3 SPECIAL PROGRAM Multi-Stage Cooking (SP-15) MODE (Continued) This allows the operator to cook up to 10 stages (time/ temperature setpoints) per product. Follows steps 1 and 2 above. Press until “SP-15” and “MULTI-STAGE ENABLED?”...
  • Page 51 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-3. SPECIAL PROGRAM Press and release to set temperature for step 2. MODE (Continued) Press to continue onto step 3 and follow instructions in steps n, o, p, and q. When all stages are set, you can continue to the next program mode when you press , or press and hold to exit...
  • Page 52 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-3. SPECIAL PROGRAM Energy Save Enabled? (Gas fryers only) (SP-17) MODE (Continued) The Energy Save mode reduces energy used during idle (non- cooking) periods by turning off the blower (draft fan) and pilot flame when possible. Follow steps 1 and 2 above.
  • Page 53: Clock Set Mode

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-4. CLOCK SET MODE This mode allows the operator to set the time and date into the controls. Press and hold for 5 seconds until “L-2” and “LEVEL 2”, followed by, “SP PROG” shows in the display.
  • Page 54: Data Logging, Heat Control, Tech Mode, And Stat Mode

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 4-4. CLOCK SET MODE If in 24-hour mode, “24-HR” shows in display, and the (Continued) hour (1-24) flashes. Press to change hours. Set Minutes Press and “CS-5, SET MINUTE” shows in display. The minutes flash, and press to change.
  • Page 55: Section 5. Troubleshooting

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 SECTION 5. TROUBLESHOOTING 5-1. TROUBLE SHOOTING GUIDE Problem Cause Correction POWER switch ON • Open circuit • Plug fryer in but fryer completely inoperative • Check breaker or fuse at supply box Shortening will not •...
  • Page 56: Error Codes

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 5-2. ERROR CODES In the event of a control system failure, the digital display will show an “Error Message.” These messages are coded: “E4”, “E5”, “E6”, “E10”, “E15”, “E20”, “E-31”, “E41”, “E46”, “E54”, E-70-A & B and “E92”. A constant tone is heard when an error code is displayed, and to silence this tone, press any button.
  • Page 57 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 5-2. ERROR CODES (Continued) DISPLAY CAUSE PANEL BOARD CORRECTION “E-20 A” Vacuum switch failure Press the timer button to try the ignition process again; (stuck closed) if “E-20 A” persists check vacuum switch; refer to Technical Manual “E-20 B”...
  • Page 58: Glossary

    Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 G L O S S A R Y HENNY PENNY HOLDING CABINETS air valve a valve on the eight head fryer that allows air into the filter lines when the pump is on in the mixing mode on eight head fryers airflow switch a switch that senses the amount of airflow coming from the blower;...
  • Page 59 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 data plate a label or plate located on the right side panel of the fryer that indicates the fryer type, serial number, warranty date, and other information drain handle the handle used to open and close the drain valve drain interlock switch a microswitch that automatically shuts off the fryer heat in the event the drain valve is inadvertently opened while the fryer power switch is in the ON position...
  • Page 60 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 gas control valve an automatic dual controller that controls gas to both pilot lights and gas (gas fryers only) pressure to burners on fryers; if either pilot light goes out, the controller shuts off the gas to the other pilot light gas valve knob the knob that opens and closes the gas control valve (gas fryers only)
  • Page 61 Model OFE/OFG/OEA/OGA-341, 342 Model OFE/OFG/OEA/OGA-341, 342 power/pump switch a three-way switch located on the front control panel of the fryer that serves as an off/on switch and a filter switch product a food item cooked in the fryer rack the wire grid that slides into the carrier to hold product during the Cook Cycle setpoint a preset cooking temperature;...
  • Page 63 Henny Penny Corporation P.O.Box 60 Eaton,OH 45320 1-937-456-8400 1-937-456-8402 Fax Toll free in USA 1-800-417-8417 1-800-417-8434 Fax *FM05-033-L* www.hennypenny.com Henny Penny Corp., Eaton, Ohio 45320, Revised 6-26-13...